Wuxi Consensic Electronic Technology Co., Ltd.

Wuxi Consensic Electronic Technology Co., Ltd.

Manufacturer from China
Verified Supplier
2 Years
Home / Products / Flowmeter /

50 100 200 500 800 1000SCCM 2 5 8 10 12SLPM Flowmeter

Contact Now
Wuxi Consensic Electronic Technology Co., Ltd.
Visit Website
City:wuxi
Country/Region:china
Contact Person:Mrswang
Contact Now

50 100 200 500 800 1000SCCM 2 5 8 10 12SLPM Flowmeter

Ask Latest Price
Video Channel
Brand Name :Consensic
Model Number :MFC900-P300
Place of Origin :WUXI
MOQ :Please contact us for details
Delivery Time :3-7 work days
Power supply :7~24VDC, 100mAVDC can be customized
Operating humidity :< 100% RH (no icing, no condensation)
How it is displayed :Instantaneous Flow: SLPM; Cumulative traffic: SL
Response time :67 (default)msCustomizable
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Model Comparison Table

Model Full Range Pressure Loss Exhaust Into the Atmosphere Flow Specification Selection Pipeline Connection Interface
MFC901 2000Pa 50, 100, 200, 500, 800SCCM NPT 1/8”
MFC902 5000Pa 1, 2, 3, 5SLPM NPT 1/8”
MFC903 30kPa 8, 10, 12SLPM NPT 1/8”

Key Features:

  1. High Sensitivity: Capable of detecting very small dynamic flow rates.
  2. Multi-Sensor Integration: Achieves a range ratio of 100:1 or higher through integration on a single chip.
  3. High Impact and Condensate Resistance: Robust sensor design to withstand impacts and resist condensation.
  4. Thermal Mass Flow Measurement: Ensures high-precision flow measurement without needing temperature and pressure compensation.
  5. Fast Response Time: Quick reaction to changes in flow conditions.
  6. High Zero-Point Stability: Maintains stable zero-point measurement.
  7. Low Power Consumption and Pressure Loss: Efficient operation with minimal energy usage and pressure drop.
  8. Versatile Output Modes: Data can be uploaded via communication interface, queried by an upper computer, or output as a linear analog signal.
  9. High Stability and Precision: Reliable measurement performance with excellent repeatability.
  10. Threaded Connection: Easy installation and use with standard threaded connections.

Performance Parameters:

  • Specifications: 50, 100, 200, 500, 800, 1000 SCCM; 2, 5, 8, 10, 12 SLPM
  • Scale Ratio: 100:1
  • Power Supply Voltage: 7~24VDC, 100mA (customizable)
  • Accuracy: ±1.0 %FS
  • Repetitiveness: 0.25 %
  • Response Time: 67 ms (default, customizable)
  • Maximum Pressure: 1.0 MPa
  • Communication Mode: RS 485 (MODBUS)
  • Output Method: Analog output of 0.5-4.5 VDC, LoRa (optional)
  • Display Mode: Instantaneous flow (SLPM); cumulative flow (SL)
  • Temperature: Medium temperature (-10~65℃), ambient temperature (-25~85℃)
  • Working Humidity: <100% RH (no ice, no condensation)
  • Weight: 0.295 kg
  • Connection: NPT 1/8” (customizable)
  • Valve Type: Normally closed
  • Calibration Conditions: Air, at 20℃, 101.325kPa

Output Pin Definitions:

Pin Number Definition Explanation
1 VDC External power supply positive pole
2 GND External power supply negative pole
3 485A RS 485A
4 485B RS 485B
5 VOUT Analog voltage output signal
6 GND Public ground
7 NC Not connected
8 NC Not connected
9 NC Not connected
Inquiry Cart 0