Example Calculation
For a CAFS500X sensor with a full range flow of 100 slpm:
If the output voltage (VOUT) is 2.5V: Instantaneous flow rate=(4V2.5V−1V)×100slpm=37.5slpmSpecifications
Model |
Latus Rectum |
Joggle |
Long |
High |
Width |
Path diameter |
Specifications |
CAFS5006 |
6 |
1/4’’ |
83 |
27 |
35 |
6 |
10 / 20 / 30 / 50 units (L/MIN) |
Product Features
- High Accuracy: ±1.5% FS accuracy ensures precise flow measurements.
- Linear Output: Provides consistent and reliable linear output without the need for temperature compensation.
- Long-term Stability: Minimal zero-drift ensures stable performance over time.
- Quick Response Time: Customizable response time, with a default of 20 ms.
- Wide Flow Range: Measures flow rates from 0-60 m/s, with strong impact resistance up to 100g.
- Robust Design: Solid-state sensing core without surface cavities or fragile films, resistant to blockage and pressure impact.
- Versatile Output Types: Offers analog voltage output (1 to 5V) and digital I2C communication output.
- Humidity Resistance: Can measure relatively humid gases and withstand condensate water.
- Operating Temperature Range: Functions effectively from -25°C to 65°C, with a storage temperature range of -40°C to 85°C.
- Protection Level: IP40 rating for durable performance in harsh conditions.
- Flow Rate Calculation: Flow rate is calculated using the formula: text{Flow rate} = left(frac{text{VOUT} - 1V}{4V}right) times text{Full range flow rate}Flow rate=(4VVOUT−1V)×Full range flow rate
Functional Items
Model: CAFS5006
Performance Parameters
Parameter |
Value |
Unit |
Remarks |
Flow Range |
10 / 20 / 30 / 50 |
slpm |
Customizable |
Power Supply Voltage |
8~24VDC, 50mA |
VDC |
Selectable |
Accuracy |
±1.5 |
% FS |
|
Response Time |
20 (Selectable) |
ms |
|
Maximum Pressure |
0.8 |
MPa |
Customizable |
Communication Mode |
485/I2C |
|
Selectable |
Output Method |
Analog outputs of 1-5V |
V |
|
Temperature |
Medium temperature (-10~65) |
°C |
|
Joggle |
G1/4 |
|
Customizable |
Levels of Protection |
IP40 |
|
|
Calibration Method |
Air, 0℃, and 20℃ 101.325kPa |
|
|
Overall Material |
Aluminum alloys (optional stainless steel) |
|
|