Wuxi Consensic Electronic Technology Co., Ltd.

Wuxi Consensic Electronic Technology Co., Ltd.

Manufacturer from China
Verified Supplier
2 Years
Home / Products / Wide Range Of Optional Gas Sensors /

CAFS1000A Service Voltage 12V DC 50mA 7 To 24V DC 0.3MPa Maximum Pressure

Contact Now
Wuxi Consensic Electronic Technology Co., Ltd.
Visit Website
City:wuxi
Country/Region:china
Contact Person:Mrswang
Contact Now

CAFS1000A Service Voltage 12V DC 50mA 7 To 24V DC 0.3MPa Maximum Pressure

Ask Latest Price
Video Channel
Brand Name :Consensic
Model Number :CAFS1000A
Place of Origin :WUXI
MOQ :Please contact us for details
Price :Offline conversation or face-to-face discussion
Payment Terms :L/C/Ade/Pellet/Texi Union, MoneyGram, Alipay, and business-to-business payments
Supply Ability :999
Delivery Time :3-7 work days
Repeatability :<0.5%
Operating Temp :-40~125℃
Maximum Pressure :0.3 MPa
Service Voltage :12 VDC, 50 mA (or 7 to 24 VDC range)
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

CAFS1000A Service Voltage 12 VDC, 50 mA (or 7 to 24 VDC range)

Product Description

The CAFS1000 series MEMS air flow sensor, also known as an air flow meter, is used in modern automotive electronic control fuel injection systems (EFI). Typically installed in the intake path between the air filter and the throttle body, it measures the amount of air entering the engine. The sensor's output signal is a key parameter in the vehicle's fuel injection system, determining fuel injection quantity and thus impacting engine performance, fuel economy, and emission standards.

For the electronic fuel injection engine to achieve optimal fuel-air mixture ratios under various operating conditions, it must accurately measure the air intake at each moment. This measurement serves as the primary basis for the ECU (Electronic Control Unit) to calculate and control fuel injection. Therefore, the air flow sensor plays a crucial role in saving energy and reducing emissions in modern vehicles.

Product Features

  • Thermal Mode Silicon Sensor Core Technology
  • Flow Measurement Range: 10~800 kg/h
  • Measurement Accuracy: (△m/Qm) ≤ ±2%
  • Output Options: Frequency output or analog voltage output (selectable)
  • Response Time: ≤ 15 ms
  • Wide Operating Voltage Range: 7~24 VDC
  • Operating Current: < 0.05A (default 14 VDC)
  • Operating Temperature: -40℃~+125℃
  • Precise ECU Matching Capability

Performance Specifications

Functional Items

Functional Items CAFS1000A Service Voltage 12V DC 50mA 7 To 24V DC 0.3MPa Maximum Pressure Unit Remarks
Flow Range 0-800 Kg/h Customizable
Service Voltage 12 VDC, 50 mA (or 7 to 24 VDC range) VDC
Accuracy ±2.0 % FS
Repeatability <0.5 %
Response Time 20 ms Customizable
Maximum Pressure 0.3 MPa
Output Method Analog outputs of 1-5 V Customizable
Operating Temp -40~125
Protection Level IP40
Calibration Method Air, 20℃, 101.325 kPa
Material ABS

The CAFS1000 series air flow sensors are designed for high accuracy and reliability, making them an essential component in modern automotive fuel injection systems. Their precise measurement capabilities ensure optimal engine performance and contribute significantly to energy efficiency and emission control.

Inquiry Cart 0